larger image
Applications
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.
Construction
Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay- stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6201 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core. The DC resistance at 20°C of the 6201-T81 conductors and of the standard ACSRs of the same diameter are approximately the same. Conductors of the 6201-T81 alloys are harder and, therefore, have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum.
Specifications
AAAC bare conductor meets or exceeds the following ASTM specifications :
B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
Notes
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz
Current ratings are based on 75
o
C conductor temperature, 25
o
C ambient, 2ft/s wind, 96/watts/sq.ft sun, 0.5 coefficients of emissivity and absorption.
Results per Page :
25
50
100
200
Results 1 - 14 of 14
1
Item #
Size KCM
Strand
Approx EC Cond. with Equivalent Resistance
Stranding
Diameter Indiv. Wire
Diameter Complete Cable
Cross Sectional Area
Weight Per 1000ft
Rated Breaking Strength
Rating
Akron
30.58
7/w
6
6/1
.0661 Inches
.198 Inches
.0240 sq.inches
28.7 Lbs
1110 Lbs
107 Amps
Alton
48.69
7/w
4
6/1
.0834 Inches
.250 Inches
.0382 sq.inches
45.7 Lbs
1760 Lbs
143 Amps
Ames
77.47
7/w
2
6/1
.1052 Inches
.316 Inches
.0608 sq.inches
72.7 Lbs
2800 Lbs
191 Amps
Azusa
123.3
7/w
1/0
6/1
.1327 Inches
.398 Inches
.0968 sq.inches
115.7 Lbs
4460 Lbs
256 Amps
Anaheim
155.4
7/w
2/0
6/1
.1490 Inches
.447 Inches
.1221 sq.inches
145.9 Lbs
5390 Lbs
296 Amps
Amherst
195.7
7/w
3/0
6/1
.1672 Inches
.502 Inches
.1537 sq.inches
183.7 Lbs
6790 Lbs
342 Amps
Alliance
246.9
7/w
4/0
6/1
.1878 Inches
.563 Inches
.1939 sq.inches
231.8 Lbs
8560 Lbs
395 Amps
Butte
312.8
19/w
266.8
26/7
.1283 Inches
.642 Inches
.2456 sq.inches
293.6 Lbs
11000 Lbs
460 Amps
Canton
394.5
19/w
336.4
26/7
.1441 Inches
.721 Inches
.3098 sq.inches
370.3 Lbs
13300 Lbs
532 Amps
Cairo
465.4
19/w
397.5
26/7
.1565 Inches
.783 Inches
.3655 sq.inches
436.9 Lbs
15600 Lbs
590 Amps
Darien
559.5
19/w
477.0
26/7
.1716 Inches
.858 Inches
.4394 sq.inches
525.2 Lbs
18800 Lbs
663 Amps
Elgin
652.4
19/w
556.5
26/7
.1853 Inches
.927 Inches
.5124 sq.inches
612.4 Lbs
21900 Lbs
729 Amps
Flint
740.8
37/w
636.0
26/7
.1415 Inches
.991 Inches
.5818 sq.inches
695.5 Lbs
24400 Lbs
790 Amps
Greely
927.2
37/w
795.0
26/7
.1583 Inches
1.108 Inches
.7282 sq.inches
870.4 Lbs
30500 Lbs
908 Amps